beautypg.com

Campbell Scientific Sentek EnviroSCAN EasyAG SDI-12 Manual v 3.4 User Manual

Page 25

background image

EnviroSMART & EasyAG SDI-12 Probe Manual

Copyright © 1991 – 2003 Sentek Pty Ltd All rights reserved

Page 20

Total current consumption:

250µA @ sleep

66mA @ standby

102mA @ sampling (Moisture)

126mA @ sampling (TriSCAN™)

Time to sample 1 sensor:

1.2 seconds maximum (Moisture only)

2.4 seconds maximum (TriSCAN™)

Maximum sensors supported:

5 Moisture sensors or

5 TriSCAN™ sensors

Figure 5: EasyAG® SDI-12 probe interface board layout

SDI12 data
Ground

+Vin

TTL Port

3


1

6 1