EnviroSMART & EasyAG SDI-12 Probe Manual

Copyright © 1991 – 2003 Sentek Pty Ltd All rights reserved

Page 9

Command

Response

aM!

a0139

The response indicates that 9 soil moisture values will be available within a time of 13 seconds. After

approximately 10 seconds the probe will issue a Service Request (a, where “a” is the probe

address). The controlling device will then issue Send Data commands (aDn!) to read the values.

Command

Response

aD0!

a+001.0000+001.1234+000.0200

aD1!

a+000.1234+000.0000+123.1234

aD2!

a+010.1200+000.1243+044.8750

If there are more than 9 soil moisture values, a further Start Measurement command (aM! or aMn!)

must be issued.

Command

Response

aM1!

a0117

The response indicates that another 7 soil moisture values will be available within a time of 11 seconds.

After approximately 8 seconds, the probe will issue a Service Request (a, where “a” is the

probe address), and the controlling device will then issue Send Data commands (aDn!) to read the

values.

Command

Response

aD0!

a+002.0010+003.1234+001.0200

aD1!

a+011.1234+001.0100+011.3344

aD2!

a+012.0230

Note: The Send Data commands (aDn!) must be issued in increasing order.

Salinity Values (aM2! and aM3!)

The Start Measurement command (aM! or aMn!) allows up to nine(9) values to be returned. As it is

possible to have up to sixteen(16) salinity values from the EnviroSMART SDI-12 probe interface,

two(2) Start Measurement commands (aM! or aMn!), “aM2!” and “aM3!” are required. The Send Data

command (aDn!) may return up to three(3) values.

Command

Response

aM2!

a0239

The response indicates that 9 salinity values will be available within a time of 23 seconds. After

approximately 21 seconds the probe will issue a Service Request (a, where “a” is the probe

address). The controlling device will then issue Send Data commands (aDn!) to read the values.

Command

Response