PConnectCE for the Pocket PC Handhelds
Campbell Scientific uses the following PakBus addresses for its
software:
NOTE
PConnect/PConnectCE 4091
PC200W 4092
PC400
4093
LoggerNet 4094
4.7 Updating Table Definitions for PakBus Dataloggers
PakBus dataloggers have table definitions stored in internal memory. Table
definitions define the structure of the data tables and the names of the
associated variables. Communication software uses these table definitions to
display and collect the data. If a new program is downloaded to the datalogger
by some means other than PConnectCE, or if the program is edited in any way,
the table definitions that the software has stored and the actual table definitions
in the datalogger may not match. In most instances, PConnectCE will
automatically update the table definitions. However, there may be times when
PConnectCE displays a message asking that the table definitions be updated
manually (or reset).
To manually update the table definitions, highlight the datalogger on the main
Station window and select Edit. From the bottom of the Station Editing
window, select Tools and choose Reset Table Definitions.