5 hidden commands, 6 datalogger talk through mode, Parts overview – Campbell Scientific CS725 Snow Water Equivalency Sensor User Manual
Page 25: Hidden commands, Datalogger talk through mode
CS725 Snow Water Equivalency Sensor
The file to retrieve will then be selected using the Hyper Terminal
function.
19. [%Rhard][%Rboot]
[%Rhard] restarts the software processor.
[%Rboot] restarts the firmware and it has the same effect as a power off
/power on.
20. [UU]
[UU] CS725/Terminal synchronizing sequence for rates other than 9600
bauds
The [UU] command synchronizes the baud rate of the CS725 to the
terminal baud rate.
6.5 Hidden Commands
Two commands are intentionally hidden from the Main menu to avoid
inadvertent use of them. These two hidden commands are as follows:
[.edata]
The [.Edata] command is used to erase all internal data memory. Do not use
this command unless you are very sure that the data is no longer required in the
CS725. Once executed, this command cannot be reversed and ALL DATA IS
LOST.
[.0xw]
The [.0xw] command is used to upload new firmware into the CS725. The “0”
character is the number zero. Please refer to Section 11, Firmware Update, for
more details.
6.6 Datalogger Talk Through Mode
Users who use Campbell Scientific dataloggers such as the CR800, CR1000, or
the CR3000 can communicate to the CS725 directly using the serial talk
through mode feature in Loggernet’s Terminal Emulator Mode.
This will allow users to access the CS725 remotely via the datalogger, so that
they can remotely do tasks such as change settings or update the CS725 clock.
7. Parts Overview
The following diagram shows a standard CS725 and some of its included
accessories.
The optional collimator is shipped in a box separate from the CS725 due to its
weight. You will also find a carrying strap for the collimator to facilitate
carrying the part.
17