CS725 Snow Water Equivalency Sensor

FIGURE 4-1. CS725 connection to DB9F-TERM

When connecting the CS725 to a computer, a power source is required to
power the CS725. A good quality regulated +12 Vdc power source should be
used such as a bench power supply or a +12 Vdc battery. It is recommended to
disconnect the cable from the CS725 while terminating the cable connections.
After the connections are verified, the connector can be reconnected to the
CS725.

5. Terminal Setup for RS-232 Communications

The following are the settings required for the terminal program to
communicate with the CS725. Typical programs include Hyperterminal or
Procomm.

Baud Rate:

9600 (Default)

Data Bits:

8

Parity:

None

Stop Bits:

1

Flow Control:

None

Local Echo:

Enabled

Terminal Mode: ANSI

Send Line Ends
with Line Feeds: Disabled