Campbell Scientific CS725 Snow Water Equivalency Sensor User Manual
Page 15
CS725 Snow Water Equivalency Sensor
4. [.hl]
The [.hl] command is used to obtain a graphical representation of the
current histogram results. This information would normally be used for
diagnostics or by a user who requires an analysis of the gamma radiation
spectrum. The command produces a log scale graph as follows:
5. [.hr]
The [.hr] command is used to verify radiation counts in manual mode. The
[.hr] command would normally be used in the process of qualifying a site
for adequate background radiation counts and is used in conjunction with
the [.a] command. See the [.a] command for details.
Please note that the [.hr] command can take several minutes to complete.
When the command is entered, the [.hr] command will immediately report
the duration of the current manual count time as follows:
-Elapsed time,current histo : 00:03:59 (HH:MM:SS)
Wait for the calculation to complete...
There will then be a pause that can take several minutes. After the pause,
a histogram will be output followed by the radiation count summary. The
summary will report three lines; the duration of the counting, the position
of the potassium peak and its processed count value, the position of the
thallium peak and its processed count value. The output format after the
histogram is as follows:
7