4 detailed main menu command information, Detailed main menu command information – Campbell Scientific CS725 Snow Water Equivalency Sensor User Manual
Page 13

CS725 Snow Water Equivalency Sensor
The menus can be switched between English and French. To change the
language setting, key the command .L
either English or French. The English version of the Main menu is as follows:
*** LIST OF COMMANDS ****
[.l]
Language (French or English)
[.h]
Read the current live histogram
[.hp]
Display the K and Tl peak positions from the live histogram
[.hl]
Display the current histogram in log scale
[.hr]
Display results after completionof a manual measurement (histogram,
position and #counts K and TI).
[.e]
Same as
[.a]
Special command: define start/stop time limits for one measurement
[.t]
Display temperature data in °C
[.d]
Display date and time
[.dd]
Modify date and time
[.hd]
Read back histograms from EPROM according to selected dates
[.f]
Read back measurement results from EPROM according to dates
[.fl]
Read back the current day measurement results
[.flla]
Read back last calculated line result
[.fs]
Read back calculated line result in short form ? (Time and EENS
only)
[.p]
Display Parameter menu
[.s]
Display status and current measurement information
[.0xps] Parameters save to file function
[.0xpr] Parameters recovery from file function
[%Rhard]/[%Rboot] Restart
software processor/reboot firmware
[UU]
CS725/terminal synchronizing sequence for rates other than 9600 bps
6.4 Detailed Main Menu Command Information
1. [.l]
The [.l] command is used to set the language setting to either French or
English.
The following menu is activated once the [.l] command is received:
[0] Francais
[1] English
Type the number 0 for French or the number 1 for English followed by
5