beautypg.com

Cs500 temperature and relative humidity probe, General, Specifications – Campbell Scientific CS500-L Temperature and Relative Humidity Probe User Manual

Page 5: 1 temperature sensor

background image

1

CS500 Temperature and Relative
Humidity Probe

1. General

The CS500 Temperature and Relative Humidity probe contains a Platinum
Resistance Temperature detector (PRT) and a Vaisala INTERCAP® capacitive
relative humidity sensor.

The -L option on the model CS500 Temperature and Relative Humidity probe
(CS500-L) indicates that the cable length is user specified. This manual refers
to the sensor as the CS500.

2. Specifications

Operating Temperature: -40

°C to +60°C

Storage Temperature: -40

°C to +80°C

Probe Length: 6.8 cm (2.66 in.)

Probe Body Diameter: 1.2 cm (0.47 in.)

Filter: 0.2

µm Teflon membrane

Filter Diameter: 1.2 cm (0.47 in.)

Housing Material: ABS Plastic

Power Consumption: <2 mA

Supply Voltage: 7 to 28 VDC

Settling Time after power is switched on: 1 second

2.1 Temperature Sensor

Sensor: 1000

Ω PRT, DIN 43760B

Temperature Measurement Range: -40

°C to +60°C

Temperature Output Signal range: 0 to 1.0 VDC