Campbell Scientific CS105/CS105MD Barometric Pressure Sensor User Manual
Page 14

CS105/CS105MD Barometric Pressure Sensor
Example 5. CR10(X) Program for Measuring the CS105 Once Every Hour with Instruction 2
(Differential Measurement)
;{CR10X}
;
*Table 1 Program
01: 10
Execution
Interval
(seconds)
01: If time is (P92)
1: 59
Minutes (Seconds --) into a
2: 60
Interval (same units as above)
3: 41*
Set Port 1* High
02: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 60
Interval (same units as above)
3: 30
Then
Do
03: Volt (Diff) (P2)
1: 1
Reps
2: 25*
± 2500 mV 60 Hz Rejection Range
3: 4*
DIFF
Channel
4: 1*
Loc [ P_mb ]
5: .184
Mult
6: 600
Offset
04: Do (P86)
1: 51*
Set Port 1* Low
05: End (P95)
06: If time is (P92)
1: 0
Minutes (Seconds --) into a
2: 60
Interval (same units as above)
3: 10
Set Output Flag High (Flag 0)
07: Real Time (P77)
1: 0110
Day,Hour/Minute
08: Sample (P70)
1: 1
Reps
2: 1*
Loc [ P_mb ]
-Input Locations-
1 P_mb
*
Proper entries will vary with program and datalogger channel, and input location assignments.
** On the 21X use the 5000 mV slow range.