Am16/32b specifications, 1. am16/32b relay multiplexer, Case (figure 2-1) – Campbell Scientific AM16/32B Relay Multiplexer User Manual
Page 13

AM16/32B Relay Multiplexer
FIGURE 2-1. AM16/32B Relay Multiplexer
3. AM16/32B Specifications
Power*:
Unregulated 12 Vdc
Minimum
Operating Voltage:
from –55° to +40°C = 11.3 Vdc
from +40° to +85°C = 11.8 Vdc
FIGURE 3-1 for relay actuation times vs.
temperature and supply voltage.)
Current Drain
Quiescent: <210
µA
Active:
6 mA typical in “2 x 32” mode
11 mA typical in “4 x 16” mode
Reset*:
A continuous signal between 3.3 Vdc and
8 Vdc holds the AM16/32B in an active state
(where a clock pulse can trigger a channel
advance). A signal voltage <0.9 Vdc
deactivates the AM16/32B (clock pulse will
not trigger a scan advance; AM16/32B is also
reset).
Clock*:
On the transition from <1.5 V to >3.3 V, a scan
advance is actuated on the leading edge of the
clock signal; clock pulse should be a minimum
of 1 ms wide; maximum voltage is 8 Vdc.
Operational Temperature
Standard:
–25° to +50°C
Extended:
–55° to +85°C
Operational Humidity:
0 to 95%, non-condensing
3
- 014A Met One Wind Speed Sensor (36 pages)
- 020C Wind Direction Sensor (26 pages)
- 024A-L Met One Wind Direction Sensor (30 pages)
- 03001-L R.M. Young Wind Sentry Set (34 pages)
- 03002, 03101, and 03301 R. M. Young Wind Sentry Sensors (40 pages)
- 034A-L WindSet (16 pages)
- 034B-L Met One Windset (34 pages)
- 036, 038 Spark Gapped Junction Box (6 pages)
- 05103, 05103-45, 05106, and 05305 R. M. Young Wind Monitors (30 pages)
- 083E Relative Humidity and Temperature Sensor (22 pages)
- 0871LH1 Freezing Rain Sensor (31 pages)
- 092 Barometric Pressure Sensor (24 pages)
- 10164-L Water Sampler Control Cable for use with Isco and Sigma Autosamplers (18 pages)
- 107-L Temperature Probe (28 pages)
- 108-LC Temperature Probe for MetData1 (12 pages)
- 108-L Temperature Probe (30 pages)
- 109-L Temperature Probe (30 pages)
- 109SS Temperature Probe (32 pages)
- 110PV Surface Temperature Probe (32 pages)
- 21108 RF450 Demo Kit (14 pages)
- 223-L Delmhorst Cylindrical Soil Moisture Block (28 pages)
- 227-L Delmhorst Cylindrical Soil Moisture Block (24 pages)
- 229 Water Matric Potential Sensor and CE4/CE8 (34 pages)
- 237-L Leaf Wetness Sensor (14 pages)
- 247-L Conductivity and Temperature (18 pages)
- 253-L and 257-L (Watermark 200) Soil Matric Potential Sensors (36 pages)
- 25458 DIN-Rail Terminal Kit (10 pages)
- 255-100 Novalynx Analog Output Evaporation Gauge (16 pages)
- 260-953 Alter-Type Wind Screen for Tipping Bucket Rain Gages (14 pages)
- 27106T Gill Propeller Anemometer (18 pages)
- 30066 Battery Terminal Bus (1 page)
- 380, 385, 380M, 385M Met One Rain Gages (22 pages)
- 3WHB10K 3-Wire Half-Bridge Terminal Input Module (14 pages)
- 43347 RTD Temperature Probe and 43502 Aspirated Radiation Shield (40 pages)
- 4386 Battery Terminal Bus (1 page)
- 4WFB120, 4WFB350, 4WFB1K 4-Wire Full Bridge Terminal Input Module (22 pages)
- 4WFBS120, 4WFBS350, 4WFBS1K 4 Wire Full Bridge Terminal Input Modules (46 pages)
- 4WPB100, 4WPB1K PRT Terminal Input Modules (16 pages)
- 52202 Electrically Heated Rain and Snow Gage (16 pages)
- 9522B Iridium Satellite Modem and COM9522B Interface Modem (46 pages)
- A100LK Anemometer (18 pages)
- A150 Desiccated Case (12 pages)
- A21REL-12 Relay Driver (10 pages)
- A6REL-12 Relay Driver (12 pages)
- AL200 ALERT2 Encoder, Modulator, and Sensor Interface (44 pages)