Met One Rain Gage Models 380 and 385

5.1.1 CR200 Series Programming

'CR200 Series
'Example program showing measurement of a 380/385 sensor every 10 seconds.

'Declare Public Variables and Units
Public Rain_in

Units Rain_in=inch

'Define Data Tables
DataTable(Table1,True,-1)

'As an example store the data every 60 minutes.

DataInterval(0,60,Min)
Totalize(1,Rain_in,False)
EndTable

'Main Program
BeginProg
Scan(10,Sec)

'MetOne 380/385 Rain Gauge measurement Rain_in:

PulseCount(Rain_in,P_SW,2,0,0.01,0)

'Call Data Tables and Store Data

CallTable(Table1)
NextScan
EndProg

5.1.2 CR1000 Programming

‘CR1000
‘Example program showing measurement of a 380/385 sensor every 10 seconds.

‘Declare Variables and Units
Public Rain_in

Units Rain_in=inch

‘Define Data Tables
DataTable (Table1,True,-1)
DataInterval

(0,60,Min,10)

‘As an example store the data every 60 minutes.

Totalize

(1,Rain_in,FP2,False)

EndTable

‘Main Program
Begin Prog
Scan

(10,Sec,1,0)

‘MetOne 380/385 Rain Gauge measurement Rain_in:

PulseCount

(Rain_in,1,1,2,0,0.01,0)

‘Call Data Tables and Store Data

CallTable

(Table1)

NextScan
End Prog