beautypg.com

Campbell Scientific 223-L Delmhorst Cylindrical Soil Moisture Block User Manual

Page 26

background image

223 Delmhorst Cylindrical Soil Moisture Block

20

14: Z=F (P30)
1: –99999

F

2:

33--

Z Loc [ WatPo_1 ]


15: End (P95)

;End then do


16: End (P95)

;End loop


17: If time is (P92)

;Output Resistance and Water Potential each
Hour

1:

0

Minutes (Seconds --) into a

2:

60

Interval (same units as above)

3:

10

Set Output Flag High (Flag 0)


18: Set Active Storage Area (P80)

;Fix the Array ID to 60

1:

1

Final Storage Area 1

2:

60

Array

ID


19: Real Time (P77)

;Output Day and Hour/Minute

1:

220

Day,Hour/Minute (midnight = 2400)


20: Sample (P70)

;Output resistances and Water Potentials

1:

64

Reps

;32 reps if not outputting water potential

2:

1

Loc [ BlockR_1 ]