beautypg.com

3 example 21x program, Example 21x program, 5. wiring for example 21x program – Campbell Scientific 223-L Delmhorst Cylindrical Soil Moisture Block User Manual

Page 24

background image

223 Delmhorst Cylindrical Soil Moisture Block


19: Real Time (P77)

;Output Day and Hour/Minute

1:

220

Day,Hour/Minute (midnight = 2400)


20: Sample (P70)

;Output resistances and Water Potentials

1:

64

Reps

2:

1

Loc [ BlockR_1 ]

7.2.5.3 Example 21X Program

21X

Multiplexer

FIGURE 7-5. Wiring for example 21X program

*Table 1 Program
01:

10

Execution

Interval

(seconds)


01: Set Port (P20)

;Enable multiplexer

1:

1

Set

High

2:

1

Port

Number


02: Beginning of Loop (P87)

;Start of measurement loop

1:

0

Delay

2:

16

Loop

Count


03: Excitation with Delay (P22)

;Clock Multiplexer to next channel

1:

1

Ex

Channel

2:

1

Delay w/Ex (units = 0.01 sec)

3:

1

Delay After Ex (units = 0.01 sec)

4:

5000

mV

Excitation


04: Step Loop Index (P90)

;Step index by 2 each pass through loop

1:

2

Step

18