beautypg.com

Appendix a. importing short cut code, A.1 importing short cut code into a program editor, Appendix a.1, importing short cut code into a – Campbell Scientific 034B-L Met One Windset User Manual

Page 23: Program editor

background image

Appendix A. Importing Short Cut Code

This tutorial shows:

How to import a Short Cut program into a program editor for

additional refinement

How to import a wiring diagram from Short Cut into the comments of

a custom program

A.1 Importing Short Cut Code into a Program Editor

Short Cut creates files that can be imported into CRBasic Editor program

editor. These files normally reside in the C:\campbellsci\SCWin folder and

have the following extensions:

.DEF (wiring and memory usage information)

.CR6 (CR6 datalogger code)

.CR2 (CR200(X) datalogger code)

.CR1 (CR1000 datalogger code)

.CR8 (CR800 datalogger code)

.CR3 (CR3000 datalogger code)

.CR9 (CR9000(X) datalogger code)

Use the following procedure to import Short Cut code into CRBasic Editor

(CR200(X), CR1000, CR800, CR3000, CR5000 CR9000(X) dataloggers).

1. Create the Short Cut program following the procedure in Section 4,

Quickstart. Finish the program and exit Short Cut. Make note of the file

name used when saving the Short Cut program.

2. Open CRBasic Editor.

3. Click

File | Open. Assuming the default paths were used when Short Cut

was installed, navigate to C:\CampbellSci\SCWin folder. The file of

interest has a “.CR6,” “.CR2”, “.CR1”, “.CR8”, “.CR3”, “.CR9”, or

“.CR5” extension, for CR6, CR200(X), CR1000, CR800, CR3000,

CR9000(X), or CR5000 dataloggers, respectively. Select the file and click

Open.

4. Immediately save the file in a folder different from \Campbellsci\SCWin,

or save the file with a different file name.

Once the file is edited with CRBasic Editor, Short Cut can no

longer be used to edit the datalogger program. Change the name

of the program file or move it, or Short Cut may overwrite it next

time it is used.

5. The program can now be edited, saved, and sent to the datalogger.

6. Import wiring information to the program by opening the associated .DEF

file. Copy and paste the section beginning with heading “-Wiring for

CRXXX–” into the CRBasic program, usually at the head of the file.

NOTE

A-1