2 mounting options, 3 wiring, Mounting options – Campbell Scientific 034B-L Met One Windset User Manual

Page 17: Wiring, 1. cm216 mount, 1. connections to campbell scientific dataloggers

background image

Met One 034B Wind Set

7.2 Mounting Options

The 034B can be attached to a CM200-series crossarm via a 17953 NU-RAIL

fitting or a CM220, Right Angle Mounting Bracket. Procedure for using these

mounts is provided in the Quickstart (Section 4.1, Step 1—Mount the Sensor).

Alternatively, the 034B can be attached to the top of a CM106B, CM110,

CM115, or CM120 tripod via the CM216, Sensor Mounting Kit. The CM216

extends 10 cm (4 in) above the mast of the tripod.

FIGURE 7-1. CM216 mount

7.3 Wiring

Connections to Campbell Scientific CRBasic dataloggers are given in TABLE

7-1. To wire an Edlog datalogger, see an older manual at

www.campbellsci.com/old-manuals

, or contact a Campbell Scientific

application engineer for assistance.

TABLE 7-1. Connections to Campbell Scientific Dataloggers

Color

Wire Label

CR6

CR9000X

CR800

CR5000

CR3000

CR1000

CR200(X)

Red

WS Signal

Pulse

P_SW

Black WS Signal Ref

Green WD Signal

SE Analog

SE Analog

Blue

WD Volt Excite Excitation (VX or EX) Excitation (VX or EX)

White WD Signal Ref

Clear Shield

9