Media Technology Systems AMX 0.2 User Manual
Page 36

Page%36%of%39%
May-10
%
The!persistence!only!applies!to!Cobranet!settings!and!not!the!DSP!
settings.!DSP!settings!will!need!to!be!stored!using!MTS!Control!and!a!
Preset!device!(see!Error!!Reference!source!not!found.).
!
If!the!persistence!tick!box!is!off,!then!no!settings!will!be!saved.!
o Mode!Rate!Control:!The!options!are!1.33mS,!2.66mS!or!5.33mS!latency.!
Note:!there!are!significant!tradeLoffs!if!changes!are!made!to!the!5.33mS!
default!settings!(see!PM25),!particularly!in!terms!of!the!number!of!switch!
hops!that!can!be!used.!If!the!ION!interface!is!being!used!with!a!simple!
local!network!with!a!single!Ethernet!switch,!then!1.33mS!can!be!safely!
used.!If!more!than!1!switch,!then!use!2.67mS.!If!more!than!3!switches,!
then!use!5.33mS.!
o The!“Location”!is!a!useful!way!of!uniquely!naming!the!ION2.0!or!ION0.2!
interface.!Up!to!60!characters,!eg!“Ballroom!3:!Stage!left,!Mics!7/8”.!For!
more!detailed!naming!information!in!a!large!project,!both!the!“Location”!
and!“Contact”!fields!can!be!used.!
!
!
!
Figure 5-4: Global Interface settings
!