beautypg.com

8 serial number query, Serial number query – Samlex America PR-3030 User Manual

Page 14

background image

14

739.704 | 11.10

Code

Description

000

After displaying the code 000, all LCD segments are displayed

and then hidden.
The controller is OK.

100

Defective solar module input. Possible causes:
• Solar module was not disconnected before the test. Check this

and repeat the test if necessary.

• Defective controller. Contact your dealer for a more detailed

examination or replacement.

010

Defective load output. Possible causes:
• Load was not disconnected before the test. Check this and

repeat the test if necessary.

• Defective controller. Contact your dealer for a more detailed

examination or replacement.

001

Defective electronic battery fuse. Possible causes:
• Solar module and load were not disconnected before the test.

Check this and repeat the test if necessary.

• Defective controller. Contact your dealer for a more detailed

examination or replacement.

011

101

110

111

• Solar module or load were not disconnected before the test.

Check this and repeat the test if necessary.

• Defective controller. Contact your dealer for a more detailed

examination or replacement.

8.8 Serial number query

Every controller has a unique serial number that can

be queried via this window. Press the right button

and the Sn will start to flash. The serial number can

now be queried by pressing the left button.
The numerals are displayed sequentially: - - - 1 2 3

4 5 6 7 8 - - - . The display can be paused and continued using the right

button.
Note the entire numeric sequence for the full serial number.

This manual is related to the following products: