beautypg.com

Samlex America TS-1500 User Manual

Page 7

background image

3. 4 Rear Panel

Battery input (+), (-).

Uti lity / AC inlet (IEC 320).

Solar panel input terminal.

Frame ground (FG).

A

B

C

D

Fig 3.2: Rear Panel (TN-1500)

5

4.Explanation of Operat ing Logic

TN -1500 (CPU control led inve rter) is des igne d to achiev e the go al o f en ergy

saving and pos sesses both UP S an d Energ y sa ving mo des . Th ese 2 modes are

us er adjus t abl e. T he unit will be facto ry s et i n the UP S m ode . D ependin g on

we at her an d util ity condi tio ns, use rs can m anu ally adj ust o r use th e monit ori ng

software to switch to the Energy sav ing mod e.

Th e main difference between UPS and En ergy saving mo de is th e amount o f

energy con served. Under t he U PS mode, the unit will remai n in the B ypa ss m ode

as long as utili ty is availabl e. Thus less energy is conserved (refer to Fi g. 4.1 for

UPS m ode control logic). Under t he E ner gy saving mode, the priority of inpu t

source cho sen is solar pan el AC m ain batt ery. If a vail able, the CP U will select

external solar panels a s its first priority in orde r to conserve en ergy. In case o f

insufficient sol ar power and uti lity f ailur e, battery power will be draw n as the last

resort. When the capacity of batteries is around 1 0~20%, the CPU wi ll re mind

end users by continuou sly sending out w arning siren unt il the system shuts d own .

B

A

D

C

AC INPUT

Chassis

Ground

Reverse Polarity
Will Damage The
Uni t.

Solar Input
(30A m ax)

NEG

POS

DC
INPUT

Cat .N o.(1 GG1 HS-212 )
Wi re Ran ge(1 0 -4 AWG Str
Cu So ldere d Wires )
Torque ( 17.7 -26.5 i n lb)

This manual is related to the following products: