E)derating – Samlex America TS-1500 User Manual
Page 18

16
Chas sis
0
10
20
30
40
50
60
70
20
40
60
80
100
21VDC
23VDC
30VDC (HORIZONTAL)
20
40
60
80
100
(E)Derating
Battery In put Voltage (V) - 24V Mode l
Ambient Tempe rature (
)
℃
Fi gure 7.2: Output Derating Curve
Figure 7.3: In put Derating Curve
1. Company N ame : Mean Well Enterprises Co Ltd
2. Model Name : 1GG1HS-191
3. Rating : 150A
4. Torque : 106.2 Ib.in max.
5. Suitable Wire : Copper wire (tem p ra ting : 75C )
6. Int ended fo r termination onto a Listed ring to ngue connector
7. To Be Sold Onl y With Install ation Instructions
8. A m oun ting screw that i s first inserted throug h the tang and is threaded
int o the con nector t o secure the connector to the tang shall be torqued
to 32 in-lbs minimum
9. Mounting Screws - Plat ed Steel . Two provided, size M 4
Cat.No.( 1G G1H S-212)
Wire Range (10-4 AWG
Str Cu Sold er ed Wires)
Torque (17. 7-26.5 in lb)
(F)
Notes on O utput L oad s:
T N /TS -1 5 00 S eri e s c an po w er m os t of equi p me nt s that nee d a n AC
s o urc e of 15 0 0W. Bu t fo r ce r tai n sp e ci fi c ty pe o f l o ad , t he uni t may n o t
work properly.
(1)Since inductive loads o r motor bas ed equipments n eed a l arge start up
(2)When the outpu t are capacit ive or rectifi ed equipments (such as swit ching
current (6~10 ti mes of i ts rated current ), pl ease make sure this start up
pow er supply), we suggest operating these equipment a t no load or light
load condition. Increase the loads slight ly only after the TN/TS-1500 ha s
started up to ensure proper operation.
current is less than t he maximum current capability of the inverter.