Samlex America TS-1500 User Manual
Page 4

2.2 Main Specific atio n
2. 1 Features
‧True sine wave output (THD<3%)
‧Selectable UPS or Energy saving mode
‧1500W rated output
‧H igh effic iency up to 90%
‧C om plete LE D ind ication for opera ting status
‧Battery low a larm and indicator
‧Surg e power capability up to 3000W
‧O utput vo ltage / frequency selecta ble
‧Fully digital controlled
‧C om pliance to UL458 / FCC / E
/ CE
13
‧C an b e u sed for most of electronic products with AC inp ut
‧3 year glo bal warranty
‧So lar charging current 3 0A max
‧Fa st transfer time 10ms (Ty p.)
1500W max. continuously, 1750W max. for 180 seconds, 1875W max. for 10 seconds,
3000W for 30 cycle
I
N
P
U
T
C
H
A
R
G
E
R
BAT. VOLTAGE
DC CURRENT
EFFICIENCY
OFF MODE
CURRENT
DRAW
PROTECTION
CHARGE
VOLTAGE
AC CHARGE
CURRENT
SOLAR OPEN
CIRCUIT
VOLTAGE
CHARGE
SOLAR
10.5 ~ 15.0V
150A
87%
14.5V
5.5A 0 .5A
±
25Vmax
30A ma x.
Under 1 .0mA at power s witch OFF
21.0 ~ 30.0V
75A
89%
29.0V
2.7 A 0.4A
±
45Vmax
42.0 ~ 60.0V
37.5A
58.0V
1.35A 0.2A
±
75Vma x
10.5 ~ 15.0V
150A
88%
14.5V
5. 5A 0.5A
±
25Vmax
21.0 ~ 30.0V
75A
90%
29.0V
2.7A 0.4A
±
45Vm ax
42.0 ~ 60.0V
37.5A
91%
58.0V
1.35A 0. 2A
±
75Vmax
MODEL
Rated
power
O utput vol tag e
Frequency
Sur ge
Cur ren t
Fac tor y
set ting
WAVEFORM
O
U
T
P
U
T
PROTECTION
112
12 4
148
212
224
248
110V 60Hz
100 / 110 / 115 / 120V
True s ine wave (THD < 3.0%)
AC sh ort
Ove rload
Over Tem perature
、
、
2 30V 50H z
2 00 / 220 / 230 / 2 40V
Over current
battery polarity reverse by fuse
battery low shutdown
battery low alarm
、
、
、
CURRENT
2
‧TN-1500 series will autom atically detect the input sources (whether AC main or
‧With pure sine wav e output, TN/TS -1500 can provide 1500W continuously,
solar panels exist) and then adjust its internal setting. Users ca n also set up the
operatin g mode, out put voltage, frequency, and saving mode by themselves
based on their special needs, geographic area, and environmental conditions.
1750W f or 3 min utes, or 20~40A of peak current for all kinds of load such as
i nductive, capacitive, or re sisti ve. Genera l applications in clude PC, ITE,
vehicles, yachts , home applian ces, motors, power tools, industrial control
equipme nts, AV system, a nd e tc.. .
89%
60 0.1 Hz
±
5 0 0.1Hz
±