Ventilation, Installation location, 3 cm to electric or gas cookers – Siemens KI25RP60 User Manual

Page 21: 30 cm to an oil or coal-fired cooker, Connecting the appliance, Electrical connection, Installation location connecting the appliance, En 21

background image

en

21

The climate class can be found on

the rating plate. Fig. +

Note
The appliance is fully functional

within the room temperature limits

of the indicated climatic class.

If an appliance of climatic class SN

is operated at colder room temperatures,

the appliance will not be damaged up to

a temperature of +5 °C.

Ventilation

Fig. !/16
The refrigeration unit is ventilated only

via the ventilation grille in the base.

Never cover the ventilation grille or

place anything in front of it. Otherwise

the refrigeration unit must work harder,

increasing the power consumption.

Installation location

Install the appliance in a dry, well

ventilated room. The installation location

should neither be exposed to direct

sunlight nor near a heat source,

e. g. a cooker, radiator, etc. If installation

next to a heat source is unavoidable, use

a suitable insulating plate or observe

the following minimum distances to a

heat source:

3 cm to electric or gas cookers.

30 cm to an oil or coal-fired cooker.

Connecting

the appliance

After installing the appliance, wait at least

1 hour until the appliance is switched on.

During transportation the oil in the

compressor may have flowed into the

refrigeration system.
Before switching on the appliance for

the first time, clean the interior of the

appliance (see chapter “Cleaning

the appliance”).

Electrical connection

The socket must be near the appliance

and also freely accessible following

installation of the appliance.
The appliance complies with the

protection class I. Connect the appliance

to 220–240 V/50 Hz alternating current

via a correctly installed socket with

protective conductor. The socket must

be fused with a 10 to 16 A fuse.
For appliances operated in

non-European countries, check whether

the stated voltage and current type

match the values of your mains supply.

This information can be found on the

rating plate. Fig. +

m

Warning

Never connect the appliance

to electronic energy saver plugs.
Our appliances can be used with

mains and sine-controlled inverters.

Mains-controlled inverters are

used for photovoltaic systems which

are connected directly to the national

grid. Sine-controlled inverters must be

used for isolated applications (e.g. on

ships or in mountain lodges) which are

not connected directly to the national

grid.

Climate class

Permitted ambient

temperature

SN

+10 °C to 32 °C

N

+16 °C to 32 °C

ST

+16 °C to 38 °C

T

+16 °C to 43 °C