beautypg.com

7 general purpose output, 1 introduction, 2 gpo_cmd_gpotoggle() – Matrix Orbital PK162-12 User Manual

Page 35: 3 general purpose output off

background image

7 General Purpose Output

7.1 Introduction

General purpose outputs allow you to connect devices, such as LEDs, to the PK162-12 and supply them

with up to 20mA of current at 5V. The PK162-12 has 7 GPOs which are software controlled, with functions
to turn them on/off and set the power state for the next startup.

7.2 gpo_CMD_GPOtoggle()

7.2.1 Meta

Short

Toggle Keypad/GPO mode

Remember

Yes

7.2.2 Parameters

Mode

1

0: Keypad, 1: GPO

7.2.3 Description

The 162-12 uses the same port for keypad and GPO. This command will allow you to toggle the display

between GPO or Keypad mode. To use the GPO’s send cmd 254 / 37 / 1. To go to keypad mode, cmd 254 /
37 / 0 must be sent.

7.3 General Purpose Output Off

Syntax

Hexadecimal

0xFE 0x56 [Num]

Decimal

254 86 [Num]

ASCII

254 “V” [Num]

Parameters

Parameter

Length

Description

Num

1

GPO number.

Matrix Orbital

PK162-12

31