10 keypad, 4 set startup gpo state, 1 introduction – Matrix Orbital GLK12232-25-FGW User Manual
Page 40
Syntax
Hexadecimal
0xFE 0x57 [Num]
Decimal
254 87 [Num]
ASCII
254 “W” [Num]
Parameters
Parameter
Length
Description
Num
1
GPO number.
Description
This command turns ON general purpose output [num]. The standard
GPO’s on the GLK12232-25 output 20mA of current at 5V.
NOTE
ON means the output is pulled LOW.
Remembered
Yes
9.4
Set Startup GPO state
Syntax
Hexadecimal
0xFE 0xC3 [Num] [state]
Decimal
254 195 [Num] [state]
Parameters
Parameter
Length
Description
Num
1
GPO number.
state
1
Startup state (0: Off, 1: On)
Description
This command will set the startup state for the GPO on the next power
up. A value of one will cause the GPO to be off on the next startup
while a value of one will cause the GPO to be on.
NOTE
This command does not affect the current state of the GPO.
Remembered
Always
10
Keypad
10.1
Introduction
The GLK12232-25 supports up to a 25 key, matrix style, keypad and may be configured to allow key
presses to be automatically transmitted via RS-232 or polled through I
2
C. The GLK12232-25 also allows
for auto-repeating key presses, and remapping of all keypad character codes.
The connector is not keyed so the keypad will probably plug in either of two ways. The display will
not be damaged by reversing the connector. However, the keypad will generate a different ASCII character
mapping for each position. If the connector has fewer than 10 pins it should be centered on the display
connector. The keypad is scanned whenever a key is pressed;there is no continuous key scan. This means
that key presses are dealt with immediately without any appreciable latency. This also prevents electrical
noise which is often caused by continuous key scans.
Matrix Orbital
GLK12232-25