Installation Procedure for 2274 XAO:

ƽ

ESD precautions should be taken. See page 31 for details.

1. Ensure all power is off/disconnected from the circuit.

2. Connect the white wire (K) to the positive power terminal.

3. Connect the green wire (L) to the negative power terminal.

4. Connect the red wire (I) to the positive power terminal.

5. Connect the black wire (J) to the positive meter terminal.

6. Connect the negative power terminal with the negative

meter terminal.

Note: Meter should be installed on the black wire only.

If red/black wires are connected prior to the green/white

and power is connected, output may be damaged due to

overloading.

Warning: Using multiple power sources for line and loop

power is not recommended as it may cause damage to

the unit.

– 25 –

I&M008-10109-DIG Rev F 07-12_layout 10/14/13 9:45 AM Page 25