MagTek MAXI MICR RS232 User Manual
Page 26

MAXI MICR RS232 with 2-Track MSR
18
Fmt 01xx: Parsed Text Format
FC0100
- Parsed text with dashes
FC0101
- Parsed text, replace dashes with “d”
Field Labels - TR-transit, AC-account #, CK-check #, AM-amount, TP-tpc,
EP-epc
Example:
-
PTTR444455556;AC
999-222-3;CK11045
Fmt 02xx: Parsed Text Format with Error Labels
FC0200
- Parsed text with dashes
FC0201
- Parsed text, replace dashes with “d”
Error Labels - PE-parsed error, NE-no error, TR-transit error,
CK-chk # error, TC-transit check digit error,
AM-amount error, OU-on us/account# error, TP-tpc error
Examples:
-
PTTR444455556;AC999-222-3;CK11045/PENE
- PTTR111?11111;AC123456/PETR (“?” = unreadable character)
Fmt 03xx: [acct
#]
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- keep spaces and dashes
Fmt 04xx: [acct
#]
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- remove spaces and dashes
Fmt 05xx: [acct
#]
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- replace spaces and dashes with zeros
Fmt 06xx: [acct
#]
• [acct #]:
- always xx characters, zero filled;
when xx=00 all characters are sent
- replace spaces and dashes with zeros
Fmt 07xx: [acct
#]
• [acct #]:
- always xx characters, zero filled;
when xx=00 all characters are sent
- remove spaces and dashes
Fmt 08xx: [transit] [acct #]
• [transit]:
- all characters in the field
-
keep
dashes
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- remove spaces and dashes