Ss tk3 7bits property, Pre card char property – MagTek USB INSERTION READER User Manual
Page 50

USB Insertion Reader
42
Default Value:
0x23 ‘#’
Description:
This character is sent as the track 3 start sentinel for cards that have track 3
encoded in AAMVA format. If the value is 0 no character is sent. If the
value is in the range 1 – 127 then the equivalent ASCII character will be sent.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.
SS TK3 7BITS PROPERTY
Property ID:
10 (0x0A)
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0x26 ‘&’
Description:
This character is sent as the track 3 start sentinel for cards that have track 3
encoded in 7 bits per character format. If the value is 0 no character is sent. If
the value is in the range 1 – 127 then the equivalent ASCII character will be
sent.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.
PRE CARD CHAR PROPERTY
Property ID:
11 (0x0B)
Property Type:
Byte
Length:
1 byte
Get Property:
Yes
Set Property:
Yes
Default Value:
0
Description:
This character is sent prior to all other card data. If the value is 0 no character
is sent. If the value is in the range 1 – 127 then the equivalent ASCII
character will be sent.
This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.