Step 10 A
- SAVE Old XP 1.XX Local Install Files -
If
S
tep 3
and
4
were performed,
SAVE
the files below.
This was an old XP 1.XX original install. Save files to a thumb drive or network folder.
F
irst
SAVE
, then
EDIT
and
RENAME
where it states Mandatory. If the renaming is not completed as
required, the new installation will fail to work as the MtAdmin.MDB file between versions 1.XX is not
compatible with the 2.XX MtAdmin.MDB file. This is a critical Step as highlighted below
...\IntelliCAT\BinList.TXT
32bit just Copy and Save. 64bit Copy, Save, then edit th
e file
to add (x86)
to Program Files path. Click File, Save, Close
...\IntelliCAT\MtAdmin.MDB
Copy, Save, Mandatory - rename MtAdmin.MDB to
1.X_MtAdmin.MDB after saving
...\IntelliCAT\Operator(s)\MtAdmin.MDB
Copy, if present – Save, Mandatory - rename MtAdmin.MDB to
1.X_OperatorMtAdmin.MDB after saving
...\InteliCAT\MTControllers.DAT
32bit just Copy and Save. 64bit, Copy, Save, then edit th
e file
to add (x86)
to Program Files path. Click File, Save then close.
...\IntelliCAT\Card Layouts\
Copy, Save the entire folder
Step 10 B
- SAVE Old XP 2.XX Local Install Files -
If
S
teps 3
and
4
were NOT performed,
COPY
,
SAVE
the files below. This was an old XP 2.XX original
install. Save files to a thumb drive or network folder.
Step 11
- Copying old files
Copy all of the old files and folders noted above in
S
tep 10
to their respective locations:
32bit copy to C:\Program Files\MagTek\IntelliCAT\... ---
Step 10
A
64bit copy to C:\Program Files (x86)\MagTek\IntelliCAT\... ---
Step 10
B
Click
YES
to
REPLACE ALL
when copying.
Old Files from 2.XX Local Install
Mandatory Action – Save Files below
...\IntelliCAT\BinList.TXT
32bit just Copy and Save. 64bit Copy, Save, then edit t
he file
to add
(x86) to Program Files path. Click File, Save and close.
...\IntelliCAT\MTAdmin.MDB
Copy, Save
...\IntelliCAT\Operators\MTAdmin.MDB
Copy, Save the Operators folder if present
...\InteliCAT\MTControllers.DAT
32bit just Copy and Save. 64bit Copy, Save, then edit th
e file
to add
(x86) to Program Files path. Click File, Save and close.
...\IntelliCAT\Card Layouts\
Copy, Save the entire folder
...\IntelliCAT\*.UDL's
Copy, Save all the UDL's only if the [ODBC] path structure
is referencing the local PC, i.e.
C:\Program
Files\MagTek\IntelliCAT\IntelliCAT.UDL
If the [ODBC] section is referencing a
UNC or Mapped Drive Path structure
i.e. \\server1\MagTek\MagTekUDL\...
DO NOT copy the *.UDL's from the local folder.
And DO NOT TOUCH the networked UDL files.
Old Files From 1.XX Install
Mandatory action - Save Files below