MagTek IntelliCAT99875658 User Manual
Page 12

Page 12
Step 17
- Network UDL customization/creation - 1.XX conversion to 32/64bit
17A - 32bit - Customize IntelliCAT.UDL and create an Operator.UDL and a
Controller.UDL if present for a networked install
XP 1.XX to 2.XX (Win 7 32bit) - Follow the instructions in
S
tep 12 A
. The [ODBC] section will
reference a mapped drive or UNC path structure as in the example below
Change the [ODBC] to reflect new UDL's (32bit) PC
[ODBC]
CardHistConnect="File Name=\\server1\MagTek\IntelliCAT\IntelliCAT.UDL\"
HistConnect="File Name=\\server1\MagTek\IntelliCAT\IntelliCAT.UDL\"
ReportConnect="File Name=\\server1\MagTek\IntelliCAT\IntelliCAT.UDL\"
UserConnect="File Name=\\server1\MagTek\IntelliCAT\Operator.UDL\", if required
WorkQConnect="File Name=\\server1\MagTek\IntelliCAT\Controller.UDL", if required
Example of Connection Strings
The UDL connections will reference the networked Database(s):
IntelliCAT.UDL connection will use \\server1\MagTek\2.X_IntelliCAT\MtAdmin.MDB
Operator.UDL connection path will use \\server1\magTek\2.X_Operators\MtAdmin.MDB
Controller.UDL connection path will use C:\Program Files\MagTek\IntelliCAT\MtAdmin.MDB
17 B - XP 1.XX to 2.XX (Win 7 64bit)
Follow the instructions in
S
tep 12 B
. The [ODBC] section will reference a mapped drive or UNC path
structure as in the example below.
Create an IntelliCAT64.UDL, Operator64.UDL (if present) and a
Controller64.UDL if required.
On the desktop INTCAT.INI file - Change the [ODBC] section to reflect new UDL's (64bit) PC
[ODBC] -
CardHistConnect="File Name=\\server1\MagTek\IntelliCAT\IntelliCAT64.UDL\"
HistConnect="File Name=\\server1\MagTek\IntelliCAT\IntelliCAT64.UDL\"
ReportConnect="File Name=\\server1\MagTek\IntelliCAT\IntelliCAT64.UDL\"
UserConnect="File Name=\\server1\MagTek\IntelliCAT\Operator64.UDL\", if required
WorkQConnect="File Name=\\server1\MagTek\IntelliCAT\Controller64.UDL", if required
Examples of Connection Strings
The UDL connections will reference the networked Database(s):
IntelliCAT64.UDL connection will use \\server1\MagTek\2.X_IntelliCAT\MTAdmin.
MDB
O
perator64.UDL connection path will use \\server1\magTek\2.X_Operators\MTAdmin.MDB
Controller64.UDL connection path will use
C:\Program Files(x86)\MagTek\IntelliCAT\MTAdmin.
MDB
17 C - XP 2.XX to Win 7 32bit
XP 2.XX to Win 7 32bit - no changes are required to the networked UDL's in use.
17 D. XP 2.XX to Win 7 64bit
Create a Controller64.UDL
if a Controller.UDL is currently referenced in the [ODBC] section
XP 2.XX to Win 7, 64bit - if a Controller.UDL is being used, leave this UDL alone. Create a new
Controller64.UDL as referenced in
Step 12 B
. The connection string will be changed to C:
\Program Files (x86)\MagTek\IntelliCAT\MTAdmin.
MDB. The path structure in the [ODBC] section
will need to be changed to reference the newly created Controller64.UDL. All other UDL's require
no changes. During the migration, IntelliCAT will utilize the old Controller.UDL and as the migration
continues, it will utilize the new Controller64.UDL. When the migration of all XP PC's has been
completed, the Controller.UDL will no longer be used.