Videotec DCTEL User Manual
Page 31
![background image](/manuals/413454/31/background.png)
Page 7
MNVCDCBD01_0442
To program the keyboard take the following steps:
1)Position DIP4 to the ON position.
NB: LED 1-8 will start blinking, this shows that the keyboard is in programming mode. LED 1-8 or 9-16 will blink
for the complete duration of the programming phase.
2)Program DCTEL / DCBD or, if required, check keyboard configuration status.
3)When programming has been completed, turn DIP4 to the OFF position. The keyboard will return to the
settled operating mode.
6.2.1 Programming the keyboard address
During the programming phase (LED 1-8 or 9-16 blinking), the keyboard address is visible at all times by
viewing the status of the monitor LED’s:
• LED Mon1 on: Address 1
• LED Mon2 on: Address 2
• LED Mon3 on: Address 3
• LED Mon4 on: Address 4
To change the keyboard address press the Monitor key until the desired address is reached.
If more than one keyboard is connected to the same matrix, make sure that each keyboard has a
different address setting. If not, conflicts could arise and/or errors could occur when carrying out video
switching and telemetry commands along the coaxial cable.
6.2.2 Programming the Video line
Video line programming is shown by LED 1-8 blinking. Press the SHIFT key if the blinking LED is 9-16.
Press keys from 1/9 to 8/16 to program matrix line status, according to the table below:
LED 1-8 Blinking.
Key
1/9
2/10
3/11
4/12
Type of Protocol
MACRO (*)
SW164OSM
LINXS
Videotec Switchers
LED On
LED Cam 1/9
LED Cam 2/10
LED Cam 3/11
LED Cam 4/12
Key
5/13
6/14
7/15
8/16
Baud Rate
1200
9600
19200
38400 (*)
LED On
LED Cam 5/13
LED Cam 6/14
LED Cam 7/15
LED Cam 8/16
(*)Default setting.
6.2.3 Programming the Telemetry line (DCTEL keyboard only)
Telemetry line programming is shown by LED 9-16 blinking. Press the SHIFT key if the blinking LED is 1-8.
Press the numeric keys from 1/9 to 8/16 to program telemetry line status, according to the two tables below:
LED 9-16 blinking.
Key
1/9
2/10
3/11
4/12
Type of Protocol
MACRO
VIDEOTEC (*)
PELCO D (**)
ENEO
LED On
LED Cam 1/9
LED Cam 2/10
Led Cam 3/11
Led Cam 4/12
Key
5/13
6/14
7/15
8/16
Baud Rate
1200
9600 (*)
19200
38400
LED On
LED Cam 5/13
LED Cam 6/14
LED Cam 7/15
LED Cam 8/16
(*) Default setting.
(**) Only 2400 Baud, fixed speed.
For the DCBD keyboard, there is no telemetry line so any settings made for the telemetry line cannot be
activated from the keyboard. So always make sure to be in the Video line programming phase with LED 1-8
blinking.