Connecting the appliance, Ventilation – Siemens GI18DA65 User Manual
Page 18
18
Note ambient
temperature and
ventilation
The climatic class can be found on the
rating plate. It specifies the ambient
temperatures at which the appliance may
be operated. The rating plate can be
found inside the appliance at the bottom
leftĆhand side.
Climatic category
Permitted ambient
temperature
SN
+10
°
C to 32
°
C
N
+16
°
C to 32
°
C
ST
+18
°
C to 38
°
C
T
+18
°
C to 43
°
C
Ventilation
The air at the back of the appliance will
heat up. This warm air must be allowed to
freely escape, otherwise the refrigerating
machine must perform more. This raises
electricity consumption. Hence, the
airĆinlet and outlet apertures should never
be covered or blocked off!
Connecting the
appliance
After installing the appliance, wait at least
½ hour until the appliance starts up.
During transportation the oil in the
compressor may have flowed into the
refrigeration system.
Before switching on the appliance for the
first time, clean the interior (see Cleaning).
The socket should be freely accessible.
Connect the appliance to 220ć240 V/
50 Hz alternating current via a correctly
installed earthed socket. The socket must
be fused with a 10 A fuse or higher.
If the appliance is to be operated in
a nonĆEuropean country, check on
the rating plate whether the indicated
voltage and current type correspond
to the values of your mains supply.
The rating plate is situated in the
bottom leftĆhand side of the appliance.
The power cord may be replaced by
an electrician only.
en