Flexible Applications

E

3

Point integrates easily with your building’s analog or digital

infrastructure as a standalone unit or network addressable
device. Here are five installation examples to make E

3

Point

work for you.

E

3

Point Standalone Dual-Gas Sensor Operation

Economical application adds
option of a second (remote) sensor
for dual gas monitoring. Two
on-board relays can activate
ventilation or strobes.

E

3

Point/BACnet (MS-TP) Configuration

E

3

Point outputs directly to BACnet or other BAS. Alarms, strobes and

horns are activated through BAS with link to DCV/HVAC controls. This
system design supports new and retrofit installations for large buildings,
and can couple with a controller to effectively integrate wired and wireless
system components. A relay output is provided as an option for activating
ventilation directly (e.g. when fan is located in close proximity to detector).

E

3

Point/Modbus Configuration

Supports Modbus protocol to daisy-chain E

3

Point detectors, providing up

to 96 points of monitoring on a serial bus. Excellent option for controller-
based (VA301C) installations common in larger applications. A relay output
is provided as an option for activating ventilation directly (e.g. when fan is
located in close proximity to detector).

E

3

Point/Wired-Wireless Hybrid Configuration

E

3

Point offers a perfect solution for applications that require a

hybrid wireless/wired system. In this configuration, E

3

Point outputs signals

to a controller (301CW) that also accepts signals from a wireless gas
detector (301W). This scheme offers great flexibility and installation cost
savings for retrofit projects. It easily handles difficult installation challenges,
such as those posed by obstructions. A relay output is provided when it
is desirable to activate fan/ventilation directly (e.g. when fan is located in
close proximity to detector).

E

3

Point Standalone Single-Sensor Operation

A low-cost application for buildings with
minimal gas monitoring requirements typical
of a small facility. Offers easy installation,
commissioning and operaton. Two on-board
relays can activate fan or strobe.

Remote

Unit

Base Unit

BACnet Communication

BAS

Wireless Network

301CW & 301W

E3Point

Network

DVC

HVAC

Alarms, Strobes, Horns

Wireless Network

301CW & 301W

BAS

Modbus Communication

Modbus Communication

Up to 3 x 32 units

E

3

Point

301C

301R8

BAS