The FTM-1 Addressable Firephone Control Module
(FlashScan® only) gives NOTIFIER's NFS-640, NFS2-640,
NFS-3030, NFS2-3030 control panels the capability to monitor
and control a circuit of up to two firefighter phones. The FTM-1
has the ability to differentiate between normal, off-hook, and
trouble conditions. This module is used to connect a remote
firefighter telephone to a centralized telephone console. A
ringing sound is provided at each off-hook handset until it is
connected to the console. The user can then connect that off-
hook phone to the main riser for the voice evac system.
Wiring to individual telephone jacks and handsets is super-
vised, and status is reported to the panel as NORMAL, TROU-
BLE, or OFF HOOK. This module has two pairs of output
termination points available for fault-tolerant wiring (Style Z),
and includes a panel-controlled LED indicator.
FlashScan® (U.S. Patent 5,539,389) is a communication pro-
tocol that greatly increases the speed of communication
between analog intelligent devices. Intelligent devices commu-
nicate in a grouped fashion. If one of the devices within the
group has new information, the panel CPU stops the group poll
and concentrates on single points. The net effect is response
speed greater than five times that of other protocols.
Features
• Supports two firefighter telephones in either NFPA Style Y
or Style Z (Fault Tolerant) telephone circuits.
• Direct-dial entry of address 01– 159 for FlashScan®.
• Built-in type identification automatically identifies itself to
the control panel.
• Internal circuitry and relay powered directly by two-wire
SLC loop.
• Integral LED “blinks” green each time a communication is
received from the control panel.
• LED blink may be deselected globally (affects all devices).
• High noise immunity (EMF/RFI).
• Wide viewing angle of LED.
• SEMS screws with clamping plates for wiring ease.
Construction
• The face plate is made of off-white Noryl®.
• Controls include two rotary switches for direct-dial entry of
address (01-159).
• The FTM-1 is configured for either a single Class B (Style
Y) or Class A (Style Z) telephone circuit.
Agency Listings and Approvals
These listings and approvals apply to the modules specified in
this document. In some cases, certain modules or applications
may not be listed by certain approval agencies, or listing may
be in process. Consult factory for latest listing status.
•
UL Listed: S635
•
ULC Listed: S635 (FTM-1A)
• FM Approved
•
CSFM: 7300-1653:0182, 7165-0028:0224, 7165-
0028:0243
•
FDNY: COA #6065, #6067
Operation
The FTM-1 uses one of 159 possible module addresses on a
SLC loop. It responds to regular polls from the control panel
and reports its type and status, including NORMAL, TROU-
BLE, or OFF HOOK status of its telephone circuits. The LED
blinks with each poll received.
Upon code command from the panel, the FTM-1 will discon-
nect the supervision and connect the telephone riser to its
telephone circuit. The telephone riser is always relay isolated
from the communication loop so that a trouble condition on the
riser will never interfere with the rest of the system.
Rotary switches set a unique address for each module. The
address may be set before or after mounting. The built-in
TYPE CODE (not settable) will identify the module to the con-
trol panel.