beautypg.com

Notifier 5451 User Manual

5451 thermal detector, 135° fixed-temperature and rate-of-rise, General

background image

DN-4760 • 01/19/95 — Page 1 of 2

GENERAL

The System Sensor 5451 plug-in rate-of-rise with fixed heat

detector contains a unique dual thermistor sensing circuit

to provide both maximum performance and solid state re-

liability. Additional features include a recess mounting op-

tion, various mounting bases, and a full line of accesso-

ries.
The 5451 thermal detector is specifically designed to meet

the stringent performance requirements of industrial and

commercial fire detection/alarm systems. The design of

these detectors emphasizes ease of installation and field

maintenance.

FEATURES

• Dual solid-state thermistor sensors.
• Fixed heat with rate-of-rise response (57.2°C/135°F alarm

point).

• Rate-of-rise feature activates when the ambient temper-

ature increases at a rate greater than 15°F (9.4°C) per

minute.

• Exceptional stability and reliability.
• Thermistor technology.
• Restorable.
• Two visible LEDs “blink” in standby and latch on in alarm.
• Sealed against back pressure.
• Three year warranty.
• Built-in test switch.
• Low standby current.
• Built-in tamper-resistant feature.
• Designed for electrical box mounting.
• 360° field viewing angle of the visual alarm LEDs.
• Easy plug-in of the head to base.
• SEMS screws for easy wiring.
• Optional recess mounting kit (flangeless bases only).
• UL listed for 50 ft. spacing.

APPLICATIONS

The 5451 135° Fixed Temperature and Rate-of-Rise Ther-

mal Detector is ideal for areas in which a smoke detector

is not practical. Independent studies show that heat de-

tectors should be used when property protection alone is

involved.

SPECIFICATIONS

Operating voltage: mounting base dependent (see chart

on page 2).
Weight: 0.6 lb. (277 g).
Size: 2" (52 mm) high, 4" (102 mm) diameter; 6.2" (158

mm) diameter with flanged bases.

S2101

MEA

167-93-E

7270-1209:105

This document is not intended to be used for installation purposes. We try to keep our

product information up-to-date and accurate. We cannot cover all specific applications or

anticipate all requirements. All specifications are subject to change without notice.

For more information, contact NOTIFIER. Phone: (203) 484-7161 FAX: (203) 484-7118

12 Clintonville Road, Northford, Connecticut 06472

5451 Thermal Detector

135° Fixed-Temperature

and Rate-of-Rise

January 19, 1995

DN-4760 • I-306

Section: Conventional Initiating Devices

Construction: flame-retardant white plastic.
Temperature: 32°F to 100°F (0°C to 37.8°C).
Humidity range: 10% to 93% RH non-condensing.
Agency listings: UL (listed for 50 ft. spacing).

ELECTRICAL RATINGS

Voltage range: 15 to 35 VDC.
Ripple voltage: 4 Vpp.
Maximum standby current: 100µA.
Input capacitance: 0.02µF.
Reset voltage: 2.50 V.
Reset time: 0.03 to 0.30 seconds.
Power-up time: 1 second maximum.

ORDERING INFORMATION

5451

Fixed heat detector with rate-of-rise. Alarm

point at 57°C (135°F). Must be mounted to

one of the 400 Series bases listed on page 2

(order separately).

RA400Z

Remote annunciator for 2- or 4-wire systems,

3 – 32 V. Use with any 400 Series plug-in

detector. Fits standard U.S. single-gang elec-

trical box.

RMK400

Recessed mounting kit. Use with any 400

Series plug-in detector. Recesses detector

by 0.8".

California

State Fire

Marshal