beautypg.com

ARI Armaturen STEVI 451 EN User Manual

Page 18

background image

Page 18

Rev. 0040306000 0410

Operating and installation instructions

3-way control valves - STEVI

®

450 / 451

DN125v-150v
- Loose nuts (pos. 24).
- Loose nuts (pos. 11).
- Detach stuffing box housing (pos. 39).
- Loose nut (pos. 4).
- Pull plug (pos. 31) down.
- Pull plug (pos. 40) with stem (pos. 41) up and

replace.

- Bolt new parts together, drill and pin them.
- Unscrew seat rings (pos. 2 bottom and top) and

renew or recondition
(For tightening torques refer to item 7.3.)

- Replace gasket (pos. 9).
- Assemble in reverse order.

(For tightening torques refer to item 7.3.)

- Secure with nuts (pos. 11) and tighten them

crosswise.
(For tightening torques refer to item 7.3.)

(top)

(bot.)

Fig. 23:
Series 450 DN125v-150v with div. plug