2 spring opens on air failure – ARI Armaturen FA800 EN User Manual
Page 6

Page 6
Rev. 0040504003 2310
Operating and installation instructions
Pneumatic actuators - FA160-800
4.5.2.2 Spring opens on air failure
DN (Inch)
1/2“
3/4“
1“
1 1/4“ 1 1/2“
2“
2 1/2“
3“
4“
5“
6“
Travel (inch)
0,24
0,24
0,32
0,32
0,51
0,51
0,63
0,79
0,98
1,26
1,58
FA160
Air supply
pressure min.
(
ps
i)
44
580
580
305
198
58
580
580
580
462
73
580
580
580
580
87
580
580
580
580
FA250
44
200
99
58
435
251
90
73
580
403
181
87
580
555
271
FA400
44
139
56
58
284
152
68
73
429
248
130
87
573
345
192
FA800
44
150
65,3
26
58
274
145
81
73
398
225
137
87
522
304
192
Requested air supply pressure for pneumatic actuators FA: max. permissible 87 psi
DN (mm)
15
20
25
32
40
50
65
80
100
125
150
Travel (mm)
6
6
8
8
13
13
16
20
25
32
40
FA160
Air supply
pressure min.
(
ba
r)
3
40
40
21,1
13,7
4
40
40
40
31,9
5
40
40
40
40
6
40
40
40
40
FA250
3
13,8
6,9
4
30
17,3
6,2
5
40
27,8
12,5
6
40
38,2
18,7
FA400
3
9,6
3,9
4
19,6
10,5
4,7
5
29,6
17,1
9
6
39,5
23,8
13,2
FA800
3
10,4
4,5
1,8
4
18,9
10
5,6
5
27,5
15,5
9,4
6
36
21
13,2
Requested air supply pressure for pneumatic actuators FA: max. permissible 6 bar