Inputs, Outputs, Table 1 - configuration – Red Lion IAMA0006 User Manual
Page 2: Block diagram
2
16. TESTS/APPROVALS:
CC
US
US
UL
R
LISTED
PROCESS CONTROL EQUIPMENT FOR
HAZARDOUS LOCATIONS
31ZN
Class I Div 2 Groups A, B, C, D T5
A) This equipment is suitable for use in Class I, Division 2, Groups A, B,
C and D or non- hazardous locations only.
B) Warning - explosion hazard - substitution of components may impair
suitability for Class 1, Division 2.
C) Warning - explosion hazard - do not disconnect equipment unless power
has been switched off or the area is known to be non-hazardous.
17. CERTIFICATIONS AND COMPLIANCES:
1
EN 61000 corresponds to IEC 1000
2
Criterion B: Temporary impairment to operational behavior that is corrected
by the device itself.
3
Criterion A: Normal operating behavior within the defined limits.
4
EN 55011 corresponds to CISPR11
5
Class A: Area of application industry.
18. CONNECTIONS: 12 AWG max., Stripping length: 0.47" (12 mm)
19. CONSTRUCTION: Polybutylenterephthalate PBT, black
20. MOUNTING: Standard DIN top hat (T) profile rail according to EN50022
- 35x7.5
21. WEIGHT: 2 oz. (54 g)
INPUTS
The IAMA accepts a full range of process signal inputs and isolates and
converts these signals to common industrial control signals. The input signal
combinations are configured by making specific DIP switch selections on the 6
and 2 position DIP switches.
OUTPUTS
As with the input choices, the process signal output of the modules is DIP
switch selectable. The maximum output current signal is 28 mA with =500
output resistance and the maximum output voltage signal is 12.5 V with =10 K
output resistance. The transmission error without adjustment is < 0.4%. Using
the potentiometer, the error can be adjusted to < 0.1%.
TABLE 1 - CONFIGURATION
Immunity to Interference According to EN 61000-6-2
1
Discharge of static electricity (ESD)
EN 61000-4-2
Criterion B
2
Electromagnetic HF field
EN 61000-4-3
Criterion A
3
Fast transients (Burst)
EN 61000-4-4
Criterion B
2
Surge voltage capacities (Surge)
EN 61000-4-5
Criterion B
2
Conducted disturbance
EN 61000-4-6
Criterion A
3
Noise Emission According to EN 50081-2
Noise emission of housing
EN 55011
4
Class A
5
Conformance With EMC Guideline 2004/108/EC And Low Voltage Directive 2006/95/EC
I,U
1
2
IN UI
GND1
5
6
OUT UI
GND2
U
U,I
DC
DC
DC
4
3
GND3
UB +
UB +
8
7
GND3
BLOCK DIAGRAM
IN
RANGES
OUT
1
DIP SWITCHES
OUTPUT (S2)
2
3
4
5
6
1
INPUT (S1)
2
0 –10 V
0 – 20 mA
off
off
off
off
off
off
off
off
4 - 20 mA
off
off
off
off
off
ON
off
off
0 – 10 V
ON
off
ON
off
off
off
off
off
2 – 10 V
ON
off
ON
off
off
ON
off
off
0 – 5 V
ON
ON
off
off
off
off
off
off
1 – 5 V
ON
ON
off
off
off
ON
off
off
2 – 10 V
0 – 20 mA
off
off
off
ON
ON
off
off
off
4 - 20 mA
off
off
off
off
off
off
off
off
0 – 10 V
ON
off
ON
ON
ON
off
off
off
2 – 10 V
ON
off
ON
off
off
off
off
off
0 – 5 V
ON
ON
off
ON
ON
off
off
off
1 – 5 V
ON
ON
off
off
off
off
off
off
0 – 5 V
0 – 20 mA
off
off
off
off
off
off
ON
off
4 - 20 mA
off
off
off
off
off
ON
ON
off
0 – 10 V
ON
off
ON
off
off
off
ON
off
2 – 10 V
ON
off
ON
off
off
ON
ON
off
0 – 5 V
ON
ON
off
off
off
off
ON
off
1 – 5 V
ON
ON
off
off
off
ON
ON
off
1 – 5 V
0 – 20 mA
off
off
off
ON
ON
off
ON
off
4 - 20 mA
off
off
off
off
off
off
ON
off
0 – 10 V
ON
off
ON
ON
ON
off
ON
off
2 – 10 V
ON
off
ON
off
off
off
ON
off
0 – 5 V
ON
ON
off
ON
ON
off
ON
off
1 – 5 V
ON
ON
off
off
off
off
ON
off
0 – 20 mA
0 – 20 mA
off
off
off
off
off
off
off
ON
4 - 20 mA
off
off
off
off
off
ON
off
ON
0 – 10 V
ON
off
ON
off
off
off
off
ON
2 – 10 V
ON
off
ON
off
off
ON
off
ON
0 – 5 V
ON
ON
off
off
off
off
off
ON
1 – 5 V
ON
ON
off
off
off
ON
off
ON
4 - 20 mA
0 – 20 mA
off
off
off
ON
ON
off
off
ON
4 - 20 mA
off
off
off
off
off
off
off
ON
0 – 10 V
ON
off
ON
ON
ON
off
off
ON
2 – 10 V
ON
off
ON
off
off
off
off
ON
0 – 5 V
ON
ON
off
ON
ON
off
off
ON
1 – 5 V
ON
ON
off
off
off
off
off
ON