beautypg.com

0 installing the display, Epax display installation, Environment and cleaning – Red Lion EPAX/MPAX User Manual

Page 4: Connecte d to must be metal pane l ma22 04x e, Dimensions in inches (mm), Figure 3, panel cut-out for the epax

background image

4

2.0 INSTALLING THE DISPLAY

EPAX DISPLAY INSTALLATION

The EPAX display is intended to be mounted

into a panel or enclosure. The display is provided

with a gasket to provide a water-tight seal. The

recommended minimum panel thickness for

NEMA 4/IP65 sealing is 0.060" (1.57 mm).

For panel mounting, prepare the panel

cut-out to the dimensions shown in

Figure 3. The supplied template may be

used to mark the cut-out and hole

locations on the panel. After the panel

cut-out has been deburred, slide the

panel gasket over the rear of the display

and onto the mounting studs. Insert the

display into the panel cut-out as

illustrated in Figure 4. Install 14 #

10-32 keps nuts (supplied) and tighten

evenly for uniform gasket compression.

Do not over-tighten the nuts.

By using additional mounting accessories,

the EPAX can be surface-wall mounted, suspended,

or bottom mounted. Separate installation instructions are

provided with the mounting accessories.

Environment And Cleaning

The display should be installed in a location that does

not exceed the maximum operating temperature and

provides good air circulation. Placing the system near

devices that generate excessive heat should be avoided.

The bezel should be cleaned only with a soft cloth and

neutral soap product. Do NOT use solvents. Continuous

exposure to direct sunlight may accelerate the aging

process of the bezel.

CAUTION

:

1

2

3

4

5

6

7

8

9

10
11

DISCONNECT AL

L

POWER BEFORE INSTALLING OR REMOVING MODULE

SLOT

TWIS

T

!

WHILE FIRMLY DEPRESSING REAR FINGER TABS (TOP & BOTTOM), INSERT SCREWDRIVER BLADE (3/16" OR 1/4") INTO NARROW SLOT

(AT THE ARROW) AND TWIST IN THE DIRECTION SHOWN

.

TO REMOVE MODULE

:

MODEL LPAX

RED LION CONTROLS

YORK, PA. MADE IN U.S.A

.

PAXCDC1

0

RS485 COMMUNICATION

12

13

14

15

- B(-)

- A(+)

- COMM

- N/C

1

2

3

4

5

6

7

8

9
10

11

~~

AC

AC

85-250VAC

50/60H

z

14V
A

COMMUNICATION OPTION

ANALOG OUT OPTION

SETPOINT (SP) OPTION

MODEL PAXD

RED LION CONTROLS

YORK, PA. MADE IN U.S.A.

SEE LITERATURE FO

R

JUMPER SELECTIO

N

SIGNAL INPUTS

USER INPUTS

VOLT/OH

M

CURRENT

+EXCITAT

ION

COMM

1

2

3

N/C

COMM

!

R

-

19

17

+

18

-

+

16

ANALOG OUTPUT

PAXCDL10

RLY3

25

21

RLY2

22

COMM

RLY1

20

QUAD RELAY S.P

.

PAXCDS20

0-10
V

ANALOG

OUTPUT

OUTPUT ANALOG

0-20mA

24

23

COMM

RLY4

RELAYS RATE

D

3A @ 250VA

C

(RESISTIVE LO

AD)

CAUTIO

N

DISCONNEC

T

ALL POWE

R

BEFOR

E

OPENING

MODULE

RETENTION
LATCH (TOP

AND BOTTOM)

MOUNTING

PANEL

PANEL

GASKET

FRONT

PANEL

MODULE RELEASE

FINGER TAB

(TOP & BOTTOM)

CASE

VENT

HOLES

REAR COVER PLATE

CONNECT THIS STUD

TO A PROTECTIVE

EARTHING SYSTEM

MOUNTING STUDS AND NUTS
(14 PLACES)

8

COMM

RST KE

Y

7

F1 KE

Y

F2 KE

Y

6

5

DSP KE

Y

PAR KE

Y

4

3

1

2

!

MODEL EPAX

MADE IN U.S.A

.

RED LION CONTROLS

YORK, PA.

RJ12

~

AC

AC

~

85 - 250VA

C

50/60Hz @ 5V

A

CAUTION: DISCONNECT

ALL POWER BEFORE INSTALL-

ING OR REMOVING MODULE.

CONNECTE

D TO

MUST BE

METAL PANE

L

MA22

04X

E

!

Figure 4, Installing The EPAX Into A Panel

2X

(123.3)

5X 4.85

(158.2 )

(170.8)

6.72

6.23

3.36

(85.4)

0.23 (5.9) DIA.

THRU, TYP.

(604.3 )

23.79

24.27 (616.5)

+.04

-.00

+1.01

-.00

+.03

-.00

+.76

-.00

DIMENSIONS In inches (mm)

Figure 3, Panel Cut-out for the EPAX