Reset, Errs, Reset errs – Vaisala WAC155 User Manual
Page 48

User's Guide ______________________________________________________________________
46 ___________________________________________________________________M210822EN-A
Example:
>inie
FACTORY DEFAULTS
>
RESET
The RESET command resets the transmitter, and takes any new
configuration settings into use. After using this command, you have to
re-open the service connection with the OPEN command.
RESET
Example:
>RESET
Wait 5 seconds delay...
ERRS
When issued alone without the [mask] option, the ERRS command
returns the current error status of the transmitter. Possible errors, their
codes, and the corresponding hexadecimal values are described in
.
You can use the [mask] option to define the set of errors that causes
NMEA messages to be marked as invalid. The error mask is a
hexadecimal number formed by combining the hexadecimal values of
the desired errors. By default the mask is 0010 which means that only if
both wind sensors are missing or broken, the NMEA data is invalid.
For example, if you want the mask to include errors 10 and 11 (0400 and
0800 in hex) , the desired mask value is 0C00:
0400 + 0800 = 0C00