Troubleshooting – State Standard Systems User Manual
Page 32
32
trouBleshootinG
proBlem
checK this
possiBle cause
corrective action
No hot water
Storage water heater
No power to auxiliary back-up
heating element
Check high temperature
protection and push reset
button on the heater
thermostat. (Use caution when
dealing with electricity.)
Storage water heater
thermostat
Thermostat defective
Replace
Thermostatic mixing valve
Improper adjustment
Check water temperature at
house faucet and adjust valve
setting
Valve defective
Replace. System must not
be run without thermostatic
mixing valve due to scald risk.
Not enough hot water
Storage water heater
Undersized for hot water
demand load
Replace
Thermostat set too low
Increase set point temperature
Element failure
Replace element
Thermostat failure
Replace thermostat
Element disconnected
Reconnect element and set
thermostat to 120°F
Check valve
Heat loss due to defective
check valve in solar pump
station
Inspect valve and repair or
replace
Cold water supply dip tube
Missing or defective
Replace dip tube
Collectors
Absorber coating degradation
Replace collector
Collector panel area
undersized
Increase collector area
Excessive condensation
Inspect and clean weep holes
and vents at bottom.
Glazing dirty
Clean as required
Leaks
Repair
Orientation
Check orientation. Face
collector within 45° of due
South
Shaded by tree(s) or other
obstructions
Remove obstacle and shading
or relocate collectors
Improper tilt
Check tilt for geographic area.
Ensure tilt is equal to latitude
plus 15°
Improperly plumbed
Compare with system
schematic and correct.
Differential Controller
Improper operation (cycling,
late turn on)
Check sensor placement
and insulation from ambient
conditions
Faulty sensor
is shown and control
reads 888.8 instead of
temperature
Sensor line break. Check the
line and repair or replace
Faulty sensor
is shown and control
reads -88.8 instead of
temperature
Short circuit. Check the line
for breaks, metal contact,
water exposure and corrosion.