27

system monitoring display

Complete monitoring display

The system monitoring display consists of 3 blocks: channel indication, the tool bar, and

system screen.

channel indication

The channel indication consists of two lines. The upper line is an alphanumeric 16

segment indication in which the channel name or menu item is shown. The lower 7

segment indication shows the channel value and the adjustment parameters are

indicated.
Temperatures are indicated in °F / °C, Temperature differences are indicated in °F / K

toolbar

The symbols in the tool bar indicate the current system status

sYmBol

standard

flashinG

Relay 1 active

Relay 2 active

Maximum tank limit reached / maximum tank

temperature exceeded.

Collector cooling function active

Antifreeze – function activated

Collector minimum temperature reached

Collector security shutdown or tank security

shutdown active (max temperature reached).
Sensor error

Manual operation active

Displayed channel indication is adjustable

Adjustment mode for displayed channel

system screen

The system screen (active system scheme) shows the scheme selected on the controller.

It consists of several component symbols, which are – depending on the current status

of the system – either flashing, permanently shown or hidden.

Blinking control symbols

• Pump is blinking while running

• Sensors are blinking if the respective sensor

indication channel is selected

• Sensors are quickly blinking if there is a sensor error

Operation control lamp indication

Constantly green:

system operation normal

Red/green blinking: initialization phase, manual

operation

Red blinking:

sensor error