Malco Gutter Outlet Punches GOP chock replacement User Manual
Malco Tools
1. Remove blade assembly mounting bolt to
disconnect blade assembly from drive rod.
(Avoid damaging blades).
2. Pull drive rod out of tool through top.
3. Remove drive chocks and release chocks,
(the springs will be loose).
4. Replace drive and release chocks while
holding the springs in position.
5. Insert drive rod through top slot and work it
through the chocks and springs and through
bottom slot.
6. Connect blade assembly to drive rod.
Top Slot
Release Chock
Drive Rod
Springs
Drive
Chocks
Bottom
Slot
Blade
Assembly
Mounting
Bolt
GOT CHOCK REPLACEMENT INSTRUCTIONS
SL10684A
Malco Products, Inc. | Annandale, Minnesota, U.S.A. | www.malcotools.com | ©2011