beautypg.com

JELD-WEN JII031 Aluminum Windows without Nailing Fin User Manual

Page 4

background image

INSTALLATION INSTRUCTIONS

for Aluminum Windows without Nailing Fin (JII031)

4

PREPARE STUD-FRAMED WALL

4

FOR RETROFIT INSTALLATIONS

After removing the old window,
remove sufficient siding to
expose enough intact building
wrap to properly seal the
window to the opening. If
damaged, apply new building
wrap in shiplap manner. Verify
the rough opening framing is
structurally sound. Continue
with the instructions.

PREPARE BUILDING WRAP

Note!

Check with the building wrap manufacturer to verify the

following steps will not void their product warranty. Follow
manufacturers' instructions.
1. Trim building wrap flush with

the rough opening.

2. At the head, cut building

wrap at 45° and tape up as
shown.

3. Trim the sides sufficiently

to allow the nailing fin to
be mounted against the
sheathing.

PREPARE SILL

1. Use self adhesive flashing to waterproof the sill.
2. Flashing must have at least 2"

of visible material below nail

fin. Flashing width must be at

least frame width + 1 3/4".

3. Measure the width of the

frame and subtract 1/4".

Transfer this measurement

from the outside edge of the

rough opening sill and draw

a line all along the rough

opening sill. This is where the

back of the flashing will sit.

4. Cut a piece of flashing the

length of the sill plus 12".

5. Place flashing on rough

opening sill, wrapping the

flashing up 6" on each jamb

as shown.

6. Pull release tape and set

flashing into place.

7. Fold the flashing down onto

the sheathing. Staple flashing

to the wall and seal the corner

edges as shown.

8. Smooth out any bubbles or

creases with a J-roller.

9. Install the continuous shim as

follows:

Note!

The continuous shim

must be 1/2" shorter than the width of the window frame, be 1/4"

narrower than the depth of the window frame sill, should level the

rough opening sill and be no more than 1/4" thick.
Align the shim on the sill flush

with the exterior and centered

between the side jambs. If

installing a mulled unit, leave

gaps at the mull joint(s) so

they don't sit on the shim and

tack into place or secure with

sealant.

45°

Interior

Width of

rough opening

12"

Continuous

support

Depth of

window

minus 1/4"

Flashing

Measure

frame

width