Toyota/lexus, 39 chapter 5 – Equus 3173 - Import Code Reader User Manual
Page 42

Toyota/Lexus
CODE RETRIEVAL PROCEDURE
39
Chapter 5
Toyota Code Retrieval Procedures (Cont)
Tool
Model
Years Eng.
Req? Perform the following:
Camry
85-93
2.0, 2.2, 2.5
Y
Procedure: Locate rectangular diag-
Celica
86-95
1.6, 1.8,
nostic connector (under hood) (T7). Plug
2.0, 2.2
Code Reader into diagnostic connector.
Corolla
89-95
1.6, 1.8
Turn ignition on. Observe “Check
Engine” light for codes.
Codes: Codes are displayed using a
series of blinks and pauses. Example:
blink-pause-blink, blink, blink = code 13
(T9). If more than one code is stored,
the lowest number code is displayed
first, followed by a 2.5 second pause,
then the next highest number code.
When all codes have been displayed,
there is a 4.5 second pause, then the
codes are repeated. Codes will continue
to cycle as long as the ignition is on
and the Code Reader is connected.
Cressida 83-89
All w/
N
Procedure: Locate “Super Monitor Dis-
Supra
87-88
“Super
play” on dashboard (T5). Push and hold
Monitor
the SELECT and INPUT M keys simul-
Display”
taneously for four seconds. DIAG will
appear on the screen. Push and hold
SET key for four seconds. View codes on
LCD display.
Codes: The screen will show OK of no
codes are present (T10). If codes are
present they will appear on the screen
screen (T10). If more than one code is
present, they will be separated by a
three second pause.
Cressida 87-92
2.8, 3.0
Y
Procedure: Locate rectangular diag-
Land
88-94
4.0, 4.5
nostic connector (under hood) (T7). Plug
Cruiser
Code Reader into diagnostic connector.
Paseo
92-95
1.5
Turn ignition on. Observe “Check
Pickup
87-95
2.4, 3.0
Engine” light for codes.
(Fl only)
Codes: If there are no codes stored in
Previa
91-95
2.4 (exc. SC)
memory, the “Check Engine” light will
Supra
87-95
3.0
blink about two times per second. If
T100
93-94
3.0
codes are stored, codes are displayed
Tercel
89-94
1.5
using a series of blinks and pauses.
4 Runner 87-95
2.4, 3.0
Example: blink-pause-blink blink
blink = code 13 (T9). If more than one
code is stored, codes are separated by
a 2.5 second pause. When all codes have
been displayed, there is a 4.5 second
pause, then the codes are repeated.