Section iv, Alignment / zeroing, 23 alignment / zeroing procedures – EOTech CNVD-T2 Clip-On Night Vision Device - Thermal 2 User Manual
Page 44: Section iv -22, Alignment / zeroing -22, 23 alignment / zeroing procedures -22, Table 2-1. reticle adjustments -22

2-22
SECTION IV
ALIGNMENT / ZEROING
2.23 ALIGNMENT / ZEROING PROCEDURES
Clip-On
WARNING
Activating ZOOM 2X when the CNVD-T2 is used
in-line with other optical sights may introduce an
error in the aiming function of those devices.
When being used in-line with an optical sight, the CNVD-T2
should be placed in ZOOM 1X, the boresight reticle should
be turned off, and zeroing procedures associated with the
primary sight should be used. Placing the CNVD-T2 in front
of an already zeroed optic / weapon combination does not
necessitate rezeroing.
Stand-Alone
Each click of the CNVD-T2 reticle moves the shot group
about 0.7cm at 25m (when in ZOOM 1X). Other click
equivalents are provided in Table 2-1. Changing the position
of the boresight reticle corresponds to a subsequent change
in shot group movement (i.e., the UP button will move the
strike of the round up).
Table 2-1. Reticle Adjustments.
Single Click Equivalents
10m
25m
100m
150m
300m
ZOOM 1X
0.3cm
0.7cm
2.6cm
3.9cm
7.9cm
ZOOM 2X
0.1cm
0.4cm
1.3cm
2.0cm
3.9cm