3-2
3.1 TROUBLESHOOTING (Continued)
Table 3-1. Troubleshooting Procedures (Continued).
Malfunction
Probable Cause
Corrective Action
1 (cont). Laser(s)
appear weak or are
not visible when
activated.
e. Battery improperly
installed.
e. Verify battery is properly
installed (section 2.2).
f. Battery power is low.
f. Replace battery
(section 2.2).
g. Battery compartment /
contacts corroded.
g. Clean battery
compartment / contacts
(section 3.2).
2. Laser(s) turn off
unexpectedly.
a. Software overload.
a. Cycle power.
b. Shut-down feature has
been initiated.
b. “Wake” the system by
pressing (single tap) the
FIRE Button, Remote Cable
Switch, or DBR.
c. Battery power is low.
c. Replace battery
(section 2.2).
d. Battery compartment /
contacts corroded.
d. Clean battery
compartment / contacts
(section 3.2).
3. ATPIAL does not
retain zero.
a. Rail grabber assembly not
properly secured to weapon
rail.
a. Verify rail grabber is
properly secured to weapon
rail (section 2.3).