beautypg.com

EOTech ATPIAL (AN/PEQ-15) - ADVANCED TARGET POINTER ILLUMINATOR AIMING LIGHT User Manual

Page 52

background image

3-2

3.1 TROUBLESHOOTING (Continued)

Table 3-1. Troubleshooting Procedures (Continued).

Malfunction

Probable Cause

Corrective Action

1 (cont). Laser(s)

appear weak or are

not visible when

activated.

e. Battery improperly

installed.

e. Verify battery is properly

installed (section 2.2).

f. Battery power is low.

f. Replace battery

(section 2.2).

g. Battery compartment /

contacts corroded.

g. Clean battery

compartment / contacts

(section 3.2).

2. Laser(s) turn off

unexpectedly.

a. Software overload.

a. Cycle power.

b. Shut-down feature has

been initiated.

b. “Wake” the system by

pressing (single tap) the

FIRE Button, Remote Cable

Switch, or DBR.

c. Battery power is low.

c. Replace battery

(section 2.2).

d. Battery compartment /

contacts corroded.

d. Clean battery

compartment / contacts

(section 3.2).

3. ATPIAL does not

retain zero.

a. Rail grabber assembly not

properly secured to weapon

rail.

a. Verify rail grabber is

properly secured to weapon

rail (section 2.3).