Power, Digital vi deo recorder, Keyboard a daptor – Clinton Electronics CE-PTZ-KEY User Manual
Page 7: Ptz camer a ce-ptzkey, Monitor dvr
7
Keyboard A
daptor
(No: 14375)
RS-232/
GND GND R
T
RS-485/
RS232 R
RS232 G
DC12V -
RS485 -
Power
DC12V
RS485 +
DC12V +
DC12V +
RS232 T
Keyboard
RJ45
Keyboard A
daptor
(included with CE-PTZKE
Y)
PTZ Camer
a
CE-PTZKEY
RS485+ (
Green Wir
e)
RS485- (Y
ellow Wire)
AC24V (Black
Wire)
AC24V (R
ed Wire)
DVR
MUX
MENU
SET/
SHO
T/
ALM/
GRP/
OFF/
ON/
AUTOP
AN/
System Keyboard
VER34<01>
AUX/
RUN/
HOLD/
PREV/
NEXT/
1
2
3
4
5
6
7
8
9
*
0
ENTER
MON
CAM
CLR
OPEN/
BACK
FAR/
PIC.L
NEAR/
PIC.F
CLOSE/
DEL
TELE/
PgDn
WIDE/
PgUp
POWER
DVR
MUX
SYS
Rx
Tx
IRIS
FOCUS
ZOOM
RJ45 Cable
Power Supply t
o Wall Outlet
Power Supply t
o Wall Outlet
BNC Connec
tion
to Monitor or DVR
Monitor
DVR
DVR
DIGITAL VI
DEO RECORDER
BNC to DVR or M
onitor
3 2 1
Installation
Connection Schematic
The keyboard can be connected to various PTZ cameras, DVRs, and Matrix devices through the
keyboard adaptor. All accessories are tested for maximum compatibility and best performance.
RS485 Cable-
The telemetric control of the device uses RS485 serial communication with half duplex
transmission technology. The transmission distance can vary, depending on cable type,
and baud rate. The following table shows maximum distances based on cable with 0,56mm
(24AWG) twisted pair:
Baud Rate
Max. Distance
2400 bps
5577ft / 1700m
4800 bps
3609ft / 1100m
9600 bps
2297ft / 700m
19200 bps
1312ft / 400m
Due to environmental interfaces, such as electromagnetic and induction fields, or number of connected
devices on the RS485 bus, or using thinner than 24AWG cable, the transmission range may be less.
For the first start, please ensure
your keyboard parameters match
those shown on the initial screen (ie.
protocol, baud-rate, ID). Doing so will
allow you to enter the OSD for further
settings.