beautypg.com

ADC AD-200 User Manual

Page 91

background image

87

2. For Direct Spark Ignition (DSI) System Models Manufactured With ADC Module Part No. 880815

a. Upon completing installation of the replacement

DSI module, reestablish power to the dryer.

b. Starting the drying cycle.

c. The ignition DSI module’s light emitting diode

(L.E.D.) indicator will light “red” for up to
approximately 1.5-seconds (prepurge time).

d. The module’s indicator light will then turn

“green.” The gas valve will be energized and
the ignitor probe will spark for approximately
8-seconds. The burner flame should now be
established.

e. With the burner flame on, remove the flame

sensor wire from the FS terminal of the DSI
module.

f. The burner flame must shut off and the ignition

module must lockout with the DSI module’s
indicator light “red.”

g. Stop the drying cycle, with the flame sensor wire

still removed, restart the drying cycle.

h. The ignition module must proceed through the prepurge, with the indicator light “red,” the ignition trial

time of approximately 8-seconds, with the indicator light “green,” and then proceed to lockout with the
indicator light “red.”

i.

Functional check of the DSI module is complete.

1) Replace the flame sensor wire from the FS terminal to the DSI module.