Third visual check – ADC AD-200 User Manual

Page 24

background image

20

j.

Troubleshooting Flowchart - Quick Reference...

Third Visual Check

Main Burner Lights But Will Not Stay On

Is flame sensor cable

securely attached

to terminal 4?

No Yes

Does continuity exist

from control

to flame sensor?

No Yes

Is flame sensor corroded

or is ceramic cracked?

No Yes

Does continuity exist in

ground path from burner

to control?

No Yes

Check flame sensing current

during trial. Is current

greater than 0.3

µ

A DC?

No Yes

Correct

Replace

sensor

cable.

Correct

Is flame sensor

positioned per

manufacturer's specifications?

Correct or

replace
sensor.

Replace

Johnson Control

module

G760/761

Correct

No Yes

Replace

Johnson Control

module

G760/761