ADC AD-200 User Manual
Page 88
![background image](/manuals/40178/88/background.png)
84
4. Basket (Tumbler) Electrical Component(s)
a. Basket (Tumbler) Thermal Magnetic Starter (TMS) and Auxiliary Contact Block Replacement
1) Discontinue electrical power to the dryer.
2) Mark and identify the wires that will be removed for proper reinstallation.
3) Set the control of the TMS to the “stop” position.
4) Press down on the TMS and lift the bottom up and out of the din mounting rail.
5) Mark and identify the wires that will be removed for proper reinstallation.
6) Remove ALL associated wires.
7) Separate the TMS from the auxiliary contact block.
8) Install new TMS or auxiliary contact block.
9) Reassemble the TMS to auxiliary contact block.
10) Set overload to required setting.