American Fibertek Net I/O N-664 User Manual
Page 5
5
Overview
Thank you purchasing your American Fibertek N-664 Net I/O. Please take a few minutes
to read these installation instructions in order to obtain the maximum performance from
this product.
The AFI V’NES (Video Network Enterprise Solution) N-664 device allows serial data and
contact closure signals to be made accessible on and linked over a network, with N-664
devices acting as transparent bridges to link together customer equipment. This permits
contact closure signals – such as door opening sensors, alarm buttons, or motion
detectors – to be linked to remote alarm annunciation, or serial data sources such as key
pads or card registers to send data to a remote monitoring system. N-664 devices can
be linked together over a standard Ethernet connection, making it possible to use a pre-
existing LAN or the Internet for device communication.
Package Checklist
Net I/O
Installation guide
Power cord
Product Features
Serial connectivity over network
Auto-detect 10/100 Ethernet connection
4 port RS232, 485 2W (Half Duplex) or 4W (Full Duplex)
Contact output (Form C, 1500KV isolated)
Alarm input (configurable as NO/NC)
Alarm transmission over network with verification and retry
Product Specifications
LAN
Ethernet
10/100 Mbps, RJ45
Protection
1500KV magnetic isolation
Serial
Serial interface
RS232/RS485
Duplex
Full or half duplex
Number of ports
4
Signals
RS2332:
TXD/RXD, CTS/RTS
RS485:
RX+/-, TX+/-
Baud rate
0 to 57600 bps